ARC-TG3
Test Generator
Purpose:
- Generating unmodulated and modulated radio signals to check operability of radio monitoring and direction finding systems afield.

ARC-TG3 Test Generator
Typical configuration:
- Test generator unit
- Remote control panel
- Power supply and charging unit with battery
- Telescopic rod antenna
- CD with software
- Carry bag
Features:
- PC-controlled or stand-alone operation
- Recording of tasks for stand-alone operation from a PC (USB 2.0 interface) or from a remote control unit
Generator provides:
- Scanning within given frequency range with set step or as per the list of frequencies (in stand-alone operation mode).
Technical Specifications
| Operating frequency range | 20 – 3000 MHz |
| Output power | 50 mW min. |
| Modulation Modes | non-modulated, angular modulation |
| Minimum tuning step | 100 kHz |
| Relative error of frequency tuning | ±5×10-7 |
| Stray emissions level in the operating frequency range (vs. the level of the basic signal) | |
| Quadratic component | minus 25 dBs max |
| Other frequencies | minus 30 dBs max |
| Phase noise level (within 10 kHz interval from the basic signal level) | minus 75 dBs max |
| Power supply voltage | |
| from AC network 50 Hz | 90 - 250 V |
| DC | 9 - 32 V |
| Power consumption in signal generation mode | 7 W, max. |
| Dimensions | 330×250×130 mm, max. |
| Weight with battery | 4 kg, max. |