Technical Specifications

Operating frequency range 20 – 8000 MHz
Attenuation 0-30 dB, incr 1 dB
IF-input 70 MHz
Receiver tuning resolution 1 Hz
Limits of allowable relative error of sine signal level measurement
by antenna inputs 1 dB
at IF input 0.5 dB
Limits of allowable relative error of field strength measurement:
using EFSU 3 dB
using external measuring antennas (K means measuring antenna calibration factor error) 1+K dB
Range of signal level measuring at switched antenna inputs: from 0 to 110 dBμV
Limits of allowable relative error of sine signal frequency measurement
when external frequency standard is used in accordance with frequency standard used
when external frequency standard is not used 5×10-8
Parameters of external reference generator input:
Frequency 10 MHz, 12,8 MHz
Level from -3 to +3 dBm
Input IP2, attenuation off:
Within 20 - 3000 MHz range 40 dBm, min
Within 3000 - 8000 MHz range 30 dBm, min
Input IP3, attenuation off:
Within 20 - 3000 MHz range 0 dBm, min
Within 3000 - 8000 MHz range 0 dBm, min
Noise figure 12 dB, max.
Phase noise level when mistuning at 10 kHz -100 dBs/Hz, max.
Standing Wave Ratio (SWR) at external antenna input with input resistance 50 Ohm 3 max.
PC control interface Ethernet 1G
External equipment control interface RS-485
Voltage of DC power supply From 10 to 32 V
Power consumption (provided that batteries are fully loaded) 40 W, max.
Continuous battery run-time 4 hours, min.
Dimensions:
Radio Receiving Unit of ARGAMAK-IN 355×270×195 mm, max.
RFSU of ARGAMAK-IN 350×200×200 mm, max.
Weight:
Radio Receiving Unit of ARGAMAK-IN 7 kg, max
RFSU of ARGAMAK-IN 2 kg, max.
Degree of protection with pluggable connectors connected IP65
Operating conditions
Ambient air temperature From -20°C to +55°C
relative humidity at 25°C up to 98
Atmospheric pressure 84 - 106.7 kPa

Other technical specifications are given in description of ARGAMAK-IN.